500-P156G-1MG
antibody from Invitrogen Antibodies
Targeting: CCL26
eotaxin-3, IMAC, MIP-4a, MIP-4alpha, SCYA26, TSC-1
Antibody data
- Antibody Data
- Antigen structure
- References [4]
- Comments [0]
- Validations
- Western blot [2]
- ELISA [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- 500-P156G-1MG - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- Eotaxin 3 Polyclonal Antibody, PeproTech®
- Antibody type
- Polyclonal
- Antigen
- Recombinant full-length protein
- Description
- AA Sequence of recombinant protein: TRGSDISKTC CFQYSHKPLP WTWVRSYEFT SNSCSQRAVI FTTKRGKKVC THPRKKWVQK YISLLKTPKQ L.
- Concentration
- 0.1-1.0 mg/mL
Submitted references An Increasing Trend of Eosinophilic Esophagitis in Korea and the Clinical Implication of the Biomarkers to Determine Disease Activity and Treatment Response in Eosinophilic Esophagitis.
Markers of eosinophilic inflammation for diagnosis of eosinophilic esophagitis and proton pump inhibitor-responsive esophageal eosinophilia: a prospective study.
Diagnostic utility of major basic protein, eotaxin-3, and leukotriene enzyme staining in eosinophilic esophagitis.
Shear-dependent eosinophil transmigration on interleukin 4-stimulated endothelial cells: a role for endothelium-associated eotaxin-3.
Kim GH, Park YS, Jung KW, Kim M, Na HK, Ahn JY, Lee JH, Kim DH, Choi KD, Song HJ, Lee GH, Dellon ES, Jung HY
Journal of neurogastroenterology and motility 2019 Oct 30;25(4):525-533
Journal of neurogastroenterology and motility 2019 Oct 30;25(4):525-533
Markers of eosinophilic inflammation for diagnosis of eosinophilic esophagitis and proton pump inhibitor-responsive esophageal eosinophilia: a prospective study.
Dellon ES, Speck O, Woodward K, Covey S, Rusin S, Gebhart JH, Chen X, Woosley JT, Shaheen NJ
Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 2014 Dec;12(12):2015-22
Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 2014 Dec;12(12):2015-22
Diagnostic utility of major basic protein, eotaxin-3, and leukotriene enzyme staining in eosinophilic esophagitis.
Dellon ES, Chen X, Miller CR, Woosley JT, Shaheen NJ
The American journal of gastroenterology 2012 Oct;107(10):1503-11
The American journal of gastroenterology 2012 Oct;107(10):1503-11
Shear-dependent eosinophil transmigration on interleukin 4-stimulated endothelial cells: a role for endothelium-associated eotaxin-3.
Cuvelier SL, Patel KD
The Journal of experimental medicine 2001 Dec 17;194(12):1699-709
The Journal of experimental medicine 2001 Dec 17;194(12):1699-709
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot: To detect Human Eotaxin-3 (CCL26) by Western Blot analysis Eotaxin 3 Polyclonal Antibody (Product # 500-P156G-1MG) can be used at a concentration of 0.1- 0.2 µg/mL. Used in conjunction with compatible secondary reagents the detection limit for Recombinant Human Eotaxin-3 (CCL26) is 1.5-3.0 ng/lane, under either reducing or non-reducing conditions.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western Blot: To detect Human Eotaxin-3 (CCL26) by Western Blot analysis Eotaxin 3 Polyclonal Antibody (Product # 500-P156G-1MG) can be used at a concentration of 0.1- 0.2 µg/mL. Used in conjunction with compatible secondary reagents the detection limit for Recombinant Human Eotaxin-3 (CCL26) is 1.5-3.0 ng/lane, under either reducing or non-reducing conditions.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Sandwich ELISA: To detect Human Eotaxin-3 (CCL26) by sandwich ELISA (using 100 µL/well antibody solution) a concentration of 0.5-2.0 µg/mL of Eotaxin 3 Polyclonal Antibody (Product # 500-P156G-1MG) is required. This antigen affinity purified antibody, in conjunction with PeproTech Eotaxin 3 Polyclonal Antibody, Biotin (Product # 500-P156GBT-1MG) as a detection antibody, allows the detection of at least 0.2-0.4 ng/well of Recombinant Human Eotaxin-3 (CCL26).