Antibody data
- Antibody Data
- Antigen structure
- References [4]
- Comments [0]
- Validations
- Western blot [2]
- Other assay [1]
Submit
Validation data
Reference
Comment
Report error
- Product number
- MA1-22700 - Provider product page
- Provider
- Invitrogen Antibodies
- Product name
- Cardiac Troponin I Monoclonal Antibody (19C7)
- Antibody type
- Monoclonal
- Antigen
- Other
- Description
- MA1-22700 detects Cardiac Troponin 1 in Human, Mouse, Rat, Bovine, Feline, Canine, Fish, Porcine, Goat, and Rabbit samples.
- Reactivity
- Human, Mouse, Rat, Bovine, Canine, Feline, Goat, Porcine, Rabbit
- Host
- Mouse
- Isotype
- IgG
- Antibody clone number
- 19C7
- Vial size
- 200 µg
- Concentration
- 4.1 mg/mL
- Storage
- 4° C, do not freeze
Submitted references The Protective Role of Yin-Yang 1 in Cardiac Injury and Remodeling After Myocardial Infarction.
End-diastolic force pre-activates cardiomyocytes and determines contractile force: role of titin and calcium.
Cardiomyocyte Hypocontractility and Reduced Myofibril Density in End-Stage Pediatric Cardiomyopathy.
Genotype-specific pathogenic effects in human dilated cardiomyopathy.
Huang Y, Li L, Chen H, Liao Q, Yang X, Yang D, Xia X, Wang H, Wang WE, Chen L, Zeng C
Journal of the American Heart Association 2021 Nov 2;10(21):e021895
Journal of the American Heart Association 2021 Nov 2;10(21):e021895
End-diastolic force pre-activates cardiomyocytes and determines contractile force: role of titin and calcium.
Najafi A, van de Locht M, Schuldt M, Schönleitner P, van Willigenburg M, Bollen I, Goebel M, Ottenheijm CAC, van der Velden J, Helmes M, Kuster DWD
The Journal of physiology 2019 Sep;597(17):4521-4531
The Journal of physiology 2019 Sep;597(17):4521-4531
Cardiomyocyte Hypocontractility and Reduced Myofibril Density in End-Stage Pediatric Cardiomyopathy.
Bollen IAE, van der Meulen M, de Goede K, Kuster DWD, Dalinghaus M, van der Velden J
Frontiers in physiology 2017;8:1103
Frontiers in physiology 2017;8:1103
Genotype-specific pathogenic effects in human dilated cardiomyopathy.
Bollen IAE, Schuldt M, Harakalova M, Vink A, Asselbergs FW, Pinto JR, Krüger M, Kuster DWD, van der Velden J
The Journal of physiology 2017 Jul 15;595(14):4677-4693
The Journal of physiology 2017 Jul 15;595(14):4677-4693
No comments: Submit comment
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis was performed on tissue extracts (30 µg lysate) of Mouse Heart (Lane 1), Rat Heart (Lane 2), Mouse Liver (Lane 3), Mouse Skeletal Muscle (Lane 4) and Mouse Brain (Lane 5). The blot was probed with Anti-Cardiac Troponin I Monoclonal Antibody (19C7) (Product # MA1-22700, 1:500 dilution) and detected by chemiluminescence using Goat anti-Mouse IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A28177, 0.25 µg/ml, 1:4000 dilution). A 24 kDa band corresponding to Cardiac Troponin I was detected only in Mouse and Rat Heart which are reported to be positive for Cardiac Troponin I expression.
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Western blot analysis was performed on tissue extracts (30 µg lysate) of Mouse Heart (Lane 1), Rat Heart (Lane 2), Mouse Liver (Lane 3), Mouse Skeletal Muscle (Lane 4) and Mouse Brain (Lane 5). The blot was probed with Anti-Cardiac Troponin I Monoclonal Antibody (19C7) (Product # MA1-22700, 1:500 dilution) and detected by chemiluminescence using Goat anti-Mouse IgG (H+L) Superclonal™ Secondary Antibody, HRP conjugate (Product # A28177, 0.25 µg/ml, 1:4000 dilution). A 24 kDa band corresponding to Cardiac Troponin I was detected only in Mouse and Rat Heart which are reported to be positive for Cardiac Troponin I expression.
Supportive validation
- Submitted by
- Invitrogen Antibodies (provider)
- Main image
- Experimental details
- Figure 1 Protein analysis in isolated cardiomyocytes from WT and HET hearts A , in HET cardiomyocytes a longer titin isoform is seen. B , Phos-tag analysis of cardiac troponin I was performed to assess its phosphorylation state. No difference in cTnI phosphorylation was seen between WT ( N = 6) and HET ( N = 5). C , immunoblot analysis was performed to measure PLN expression levels and phosphorylation. D and E , no difference was seen in expression levels ( D ) and phosphorylation at Ser16 ( E ) between WT ( N = 6) and HET ( N = 5). Data are shown as means +- SEM.